Ø 14 mm solid shaft (flange or foot mounting)
Up to 15 position switches, switching capacity 230 V AC/DC, 0.5 A
Resolution 13 bit singleturn / 15 bit multiturn
Options: Current output (4-20 mA) for real-time position data
Technical Data | |
Attribute | Value |
Supply voltage | 15-27 VDC |
Resolution |
- Multiturn 15 bit (32768 rotations) - Singleturn 13 bit (8192 steps per rotation or 0.044° = 360°/8192) |
Switching outputs | Position switches; further switching functions on request (see U-ONE-Compact) |
Signal outputs/Interfaces |
- None (switching relay only) - Current output 4-20 mA - Further interfaces (see U-ONE-Compact) |
Maximum rotation | Solid shaft: up to 2800 rpm |
Electrical connection |
- Base module: Terminal box (copper cable) + USB interface - Switching module: Terminal box (copper cable) |
Construction type / Ø shafts | Solid shaft (B5, B35) / Ø 14 mm with feather key |
Device temperature range | -25 °C to +70 °C |
Degree of protection | IP66 |
Weight | Approx. 3.6 kg + 0.8 kg/module |
Device options |
- Modularly extendable (up to 15 relay outputs or current output for real-time position data) - Further additional functions: UOC 40 - SIL 2 (DIN EN 61508); PL d (DIN EN ISO 13849); Category 3 (DIN EN ISO 13849) can be implemented with USC 42 |
Mechanical options |
- Additional foot (solid shaft construction type) - MI: Saliferous environment |
Special features and certificates | Simple replacement for mechanical rotary cam limit switches |
The position range monitors | |
The electronic position switches ERC 40 make it possible to flexibly monitor position ranges. For example, they are deployed in hoisting gear, in crane technology and in mining operations as well as in screw downs and side guides in steel works. The electronic position switches are often used as a simple 1:1 replacement solution in legacy systems where mechanical rotary cam limit switches are installed; moreover, they can also be integrated in new systems without any difficulty. They ensure high accuracy and facilitate fast and easy system calibration by means of presets, by setting switching points as well as uncomplicated data storage. |