Converts HTL in TTL or TTL in HTL
Signal level conversion, eliminate interference signals
Input and output electrically isolated by means of optocouplers
Options: Supply voltage 5 V or 12-30 V
Technical Data | |
Attribute | Value |
Product usage | Encoder signal outputs, convert (HTL in TTL or TTL in HTL) |
Supply voltage | 12-30 VDC |
Signal input | HTL (square wave 12-30 V) or TTL (square wave 2.8-6 V) |
Signal output | HTL or TTL (0°, 90°, N and respective inverted signals) |
Frequency range | 0 - 250 kHz |
Casing | Electronic housing for standard mounting rail |
Dimensions | 50 x 75 x 52 mm |
Device temperature range | -20 °C to +70 °C |
Degree of protection | IP20 |
Electrical connection | 18 pole PHOENIX COMBICON screw terminals 2.5 mm² |
Device options |
Isolated conversion of HTL in TTL or vice versa with different supply voltages - OM 3-1-1: HTL/HTL: 12 - 30 V - OM 3-1-2: TTL/HTL: 12 - 30 V - OM 3-1-3: HTL/TTL: 5 V - OM 3-1-4: TTL/TTL: 5 V - OM 3-1-5: HTL/TTL: 12 - 30 V - OM 3-1-6: TTL/TTL: 12 - 30 V |
Mechanical options | |
Special features and certificates |
The pulse transformers | |
Pulse converters are utilized for purposes of electrical isolation, signal level conversion and elimination of interference signals; they also convert HTL to TTL as well as TTL to HTL. The output stages are equipped with the latest driver ICs, and enable signal transmissions along long lengths of cables in conjunction with high output frequencies. Optocouplers isolate the inputs from the outputs. Short-circuits and output stage overload are signalled. The modules can be snapped onto standard mounting rails EN 50 022. |