Monitor overspeed and underspeed by means of 3 configurable speed switches equipped with positively driven relays
Easy configuration instead of complicated PLC programming
Switching capacity up to 250 VAC / 500 mA or 230 VDC / 180 mA
Options: Without SIL/PL certification (UO-EGS-R); combine up to 6 speed switches (= 2 modules)
Technical Data | |
Attribute | Value |
Supply voltage | Power supplied via controller module |
Signal outputs/Interfaces |
- 3 configurable speed switches, 2 NO contacts per switch, potential-free relay contacts with switching capacity: - 5...250 V / 5…500 mA AC - 5...30 V / 5…500 mA DC - 30…230 V / 5…180 mA DC - 1 switch configurable as error switch (e. g. emergency stop circuit) - Configurable functions: Hysteresis, delay, switching independent of rotational direction, safe error switch, switch test diagnostics - LED indicators: Operating conditions/warning |
Electrical connection |
- Number of screw terminals and function: - 4: Switch S1 (each 2 NO contacts) - 4: Switch S2 (each 2 NO contacts) - 4: Switch S3 (each 2 NO contacts) - Internal bus connection to preceding and following modules |
Dimensions | 100 x 25 x 110 mm (modular electronics housing for DIN rail bus connector) |
Device temperature range | -25 °C to +60 °C |
Degree of protection | IP20 (switchboard installation) |
Device options |
- Combines with other modules belonging to the U-ONE(-SAFETY)-LWL-System - Combines up to 6 speed switches (= 2 modules) - Maximum 15 switches per system, of which maximum 6 speed switches |
Mechanical options | - |
Special features and certificates | USL(H) 42 and associated modules UO-S…: SIL 2 (DIN EN 61508); PL d (DIN EN ISO 13849) |
The new speed limiters | |
The speed switch modules of the U-ONE(-SAFETY) second generation are electronic overspeed switches that monitor the defined speeds for overspeed and underspeed. They are equipped with hysteresis, a switching delay, a switching function dependent on the direction of rotation and the option of performing a switch test and can be parameterized as reliable error switches. The parameterization is carried out using input masks, meaning that complex SPS programming is not necessary. The modules are optionally available as certified up to SIL 2 / PL d. |