Monitor position ranges / electronic position switch
Relay contacts / switching outputs: 6 programmable, 1 diagnostics
Switching capacity up to 250 V AC/DC and 0.5 A
Preset input to automatically adjust at reference position
Technical Data | |
Attribute | Value |
Supply voltage | 12-30 VDC |
Signal outputs/Interfaces |
- 6 programmable position switches (changeover contact 250 V / 0.5 A AC/DC) - Status output: 1 potential-free relay output (NC contact 250 V / 0.5 A AC/DC) - Preset: 1 optorelay (preset input 12…30 V / 5 mA DC and handshake output (40 V / 0.1 A DC) - Programmable functions via decoder module UO-EM-D2 (ERCPro – software): Operating range inputs with inversion option, hysteresis value, count direction, unit, identification, last alteration (automatic input), conversion factor. - LED indicator: Power / Status / Relay status |
Electrical connection |
- Screw terminals to connect switches - Series connectors to preceding and following modules (internal bus connection) |
Dimensions | 99.5 x 45 x 114.5 mm (modular electronics housing for DIN rail) |
Device temperature range | -25 °C to +70 °C |
Degree of protection | IP20 (switchboard installation) |
Device options | Combines with other modules belonging to the U-ONE System |
Mechanical options | |
Special features and certificates | UL/CSA |
The position monitor | |
The electronic position switch with six programmable switching outputs (each with one on and one off switching points) are available with numerous functions. The number of bits for multiturn operations, singleturn or multiturn ranges as well as the switching range inputs with invert option are programmable. They determine hysteresis values, counting direction and the unit, identification, last change and conversion factor. |