Welcome To Emco Precima

UO-EPB / UO-SPB (communication module)

Inquire now
  • UO-SPB-1: Communicates safe position and speed to a safety controller via PROFIsafe protocol

  • UO-EPB-1: Communicates position and speed to a non-safety controller via PROFIBUS-DP

  • Resolution up to 13 bit singleturn / 15 bit multiturn

  • Options: Without SIL/PL certification (UO-EPB-1); it is possible to combine 2 bus modules within a system


Technical Data
Attribute Value
Supply voltage Power supplied via controller module
Signal outputs/Interfaces

- PROFIBUS-DP | UO-EPB

- PROFIsafe via PROFIBUS-DP | UO-SPB

- Resolution:

- UO-EPB: 12 bit singleturn / 15 bit multiturn

- UO-SPB: 13 bit singleturn / 15 bit multiturn

- Bus addressing with rotary coding switch

- Configurable functions:

- UO-EPB: Counting direction, resolution, limit switches

- UO-SPB: Counting direction, standstill tolerance, preset, integration time safe/unsafe, size of monitoring window

- LED indicators: Operating conditions/warning

Electrical connection

- UO-EPB: D-SUB 9 connector (1x)

- UO-SPB: M12 connector (1x)

- Internal bus connection to preceding and following modules

Dimensions

- UO-EPB: 100 x 25 x 110 mm (modular electronics housing for DIN rail bus connector)

- UO-SPB: 100 x 60 x 110 mm (modular electronics housing for DIN rail bus connector)

Device temperature range -25 °C to +60 °C
Degree of protection IP20 (switchboard installation)
Device options

- Combines with other modules belonging to the U-ONE(-SAFETY)-LWL-System

- Combine of 2 bus modules possible within one system (UO-EPN/SPN/EPB/SPB)

Mechanical options -
Special features and certificates USL(H) 42 and associated modules UO-S…: SIL 2 (DIN EN 61508); PL d (DIN EN ISO 13849)
The new position signalers with PROFIBUS
The communication modules of the U-ONE(-SAFETY) second generation transmit the position, speed and status data of the shafts that need to be monitored to a higher-level controller. They feature a PROFIBUS-DP interface. In the UO-SPB safety design (certified up to SIL 2 / PL 2), the programmable parameters reference the counting direction, the idleness tolerance, the preset value, the integration time and the size of the monitoring window. In the UO-EPB standard design, the counting direction, resolution and limit switches can be parameterized.